What a complete under canopy lighting schedule contains

Last reviewed November 18, 2026 · 7 min read

The short answer

An under canopy package is fixtures plus a control and cabling tail that is easy to under-order. One room on the sample schedule is 120 fixtures, one controller, eight power cables, eight communication lines, sixteen waterproof RJ extensions, eight splitters and eight junction boxes: 32 accessory line items against one line of light. The run count comes from the daisy chain limit, which is 20 fixtures, so 120 fixtures is 8 runs. Fixture spacing follows plant spacing, not a fixed pitch, which is why the drawing carries a field verify note.

The schedule, in full

This is one cultivation room, roughly 66 feet by 30 feet, with four double table rows. Every line below is on the sheet.

Under canopy lighting equipment schedule, one room
ItemQtyNotes
Under canopy LED fixture12045.6in long, 277V, 0.43A, 120W, two plant stands per fixture
Controller1One per room
277V power cable8One per run
Communication line, 10 ft8Splits from the power cable
Waterproof RJ extension, 1 ft8
Waterproof RJ extension, 15 ft8
Splitter8
Outlet / junction box8

One hundred and twenty fixtures, and 32 line items that are not fixtures. Every one of those accessories is a thing that has to be on site on the day the electrician is, and none of them appear on a quote that was built from a fixture count and a price each.

Where the run count comes from

The fixtures daisy chain up to twenty. That single number sets most of the rest of the schedule. One hundred and twenty fixtures divided by a twenty fixture chain gives six full chains, and the layout runs eight, because the chains follow the table rows rather than a spreadsheet.

Eight runs is why there are eight power cables, eight communication lines, eight splitters and eight junction boxes. Change the room and the fixture count changes, which changes the run count, which changes all four of those lines. This is the reason an under canopy package cannot be scaled by multiplying a per square foot figure.

Spacing follows the plants, not the drawing

Spacing as drawn
DimensionAs drawn
Between fixtures along a table3 ft 9 5/8 in
Between table rows5 ft 1 1/2 in
Room, approximate66 ft by 30 ft 5 3/4 in
Table rows4 double rows

The sheet carries a note next to those dimensions saying the spacing is approximate and should be field verified against plant spacing. That note is doing real work. Under canopy light is aimed at the lower canopy of specific plants, so the fixture pitch is derived from the plant pitch. A change in plant count or pot size between design and planting changes the fixture count, and the fixture count changes the run count.

What to check in an under canopy quote

  • Does it list splitters, junction boxes and both lengths of RJ extension, or only fixtures and a controller?
  • What is the daisy chain limit on the fixture quoted, and does the run count in the quote match it?
  • Is the fixture count derived from a plant count, or from floor area?
  • Is the connected load stated? One room at 120 fixtures and 120 watts is 14.4 kW.
  • Are the communication lines specified as waterproof? These sit under a canopy that gets irrigated.

Common questions

How many under canopy lights does a flower room need?

On the sample layout, 120 fixtures cover one room of roughly 66 by 30 feet with four double table rows, at two plant stands per fixture. The count follows plant spacing rather than floor area, which is why the drawing carries a field verify note against the spacing dimensions.

What else is needed besides the under canopy fixtures?

For 120 fixtures across eight runs: one controller, eight power cables, eight 10 foot communication lines, eight 1 foot and eight 15 foot waterproof RJ extensions, eight splitters and eight junction boxes. That is 32 accessory items against one line of fixtures.

How many under canopy fixtures can be daisy chained?

On the fixture in the sample schedule, up to 20. That limit is what sets the run count, and the run count sets the quantity of cables, splitters and junction boxes.

What is the spacing for under canopy lights?

As drawn on the sample sheet, 3 ft 9 5/8 in between fixtures along a table and 5 ft 1 1/2 in between table rows. The sheet marks these approximate and asks for field verification against plant spacing, because the fixture pitch follows the plant pitch.

How we put this together

Quantities, spacing and the daisy chain limit are read off the under canopy lighting layout and details sheets in the EES sample set. Fixture dimensions and electrical figures are the manufacturer's published specification.

Elevated designs these layouts and distributes under canopy lighting.