Reading a fertigation P&ID, from water source to emitter

Last reviewed November 18, 2026 · 8 min read

The short answer

A fertigation P&ID is read in sequence, not in plan. The sample diagram runs a 3/4 inch supply through a filter into two 750 gallon storage tanks, past six 55 gallon stock tanks into the fertigation skid, out to six 300 gallon batch tanks each with its own pump, recirculation, drain and master valve, then through 1-1/2 inch mains and 1 inch branches to a solenoid per zone in every room. Each room also carries a batch spigot and a water spigot. A plan shows where the tank sits. The P&ID shows what happens to the water.

Why fertigation gets a diagram and not a plan

Every other system in a cultivation set is drawn in plan, because the question is where it goes. Fertigation is drawn as a piping and instrumentation diagram, because the question is what order things happen in and which valve is open when.

A P&ID ignores physical position entirely. A tank that sits in the corner of the water room appears wherever the sequence puts it. What it fixes instead is every vessel, every pump, every valve, which valves are normally open and which are normally closed, line sizes, and the direction of flow. That is the information an installer and a grower both need and a floor plan does not carry.

The train, stage by stage

Fertigation train as drawn
StageOn the diagramLine size
Source3/4 inch supply, isolation either side of the filter3/4 in
FiltrationWater filter, normally open and normally closed valves around it3/4 in
StorageTwo 750 gallon filtered water tanks1 in to 2 in
PumpingFertigation pump off storage1-1/2 in
StockSix 55 gallon stock tanks, head tubing to the skidhead tubing
InjectionFertigation skid, fed from stock, out to batch1 in
BatchSix 300 gallon batch tanks, each with pump, recirculation, drain and master1 in
DistributionMains to each room, branch per zone1-1/2 in main, 1 in branch
RoomSolenoid per table zone, plus a flush zone to drain1 in

Six stock tanks and six batch tanks is not redundancy. Stock tanks hold the concentrates, and six of them is what lets a facility run more than one recipe. Batch tanks hold mixed, ready to feed solution, and one per room group is what lets flower one get a different feed from flower three on the same day without either of them waiting.

The zone level

At the room end the diagram stops being about tanks and starts being about valves. Each room on the sample P&ID is broken into zones, one per table or rack, each with its own solenoid, plus a final zone that is a flush line to drain rather than to plants.

Rooms and zones as drawn
RoomZonesExtras
Mothers5 table zones plus flushBatch spigot, water spigot
Veg and momsRack zones across 5 racks, A and B per rack, plus flushBatch spigot, water spigot
Flower 1 to 44 table zones each, plus flushBatch spigot, water spigot each

The flush zone is the one people cut. It is a line that goes to drain rather than to a plant, and on a budget set it looks like a line that waters nothing. It is what lets you clear a main of the last recipe before the next one, and without it every recipe change starts with whatever was left in the pipe.

The two spigots

Every room on the diagram carries two taps: a batch spigot, fed from the room's batch tank, and a water spigot, fed from filtered storage. They are small line items and they are the first things value engineered out of a set.

They are also the two taps a grower uses every day. The batch spigot is how you pull a sample of what the room is actually being fed, which is the only way to check the system against the recipe. The water spigot is how you hand water a tray, mix a foliar, or rinse something without breaking a zone or running a cycle. A room without them makes a grower walk to the water room for both.

Common questions

What is a P&ID in a cannabis facility?

A piping and instrumentation diagram showing every vessel, pump, valve and line in sequence rather than in physical position. Fertigation is drawn this way because the order of operations and the valve states are what make the system work, and a floor plan cannot carry either.

How many stock tanks does a commercial fertigation system need?

The sample system runs six 55 gallon stock tanks and six 300 gallon batch tanks. Stock tanks hold concentrates and their count sets how many recipes you can run; batch tanks hold mixed solution and their count sets how many rooms can be fed differently on the same day.

What is a flush zone and do I need one?

A zone that runs to drain instead of to plants, used to clear a main of the previous solution before a recipe change. Every room on the sample diagram has one. Without it, each recipe change begins with whatever was left in the pipe.

What pipe sizes are used in commercial fertigation?

On the sample diagram, 1-1/2 inch PVC mains out to the rooms, 1 inch PVC branches to each zone, a 3/4 inch incoming supply, and 2 inch on some tank runs. Sizes are on the diagram next to each line.

How we put this together

Every vessel, line size, valve and zone described is read off the piping and instrumentation diagram in the EES sample set, which is published in full in the layout library on our Technical Services page.