All resources

What a commercial flower room is actually specified with

Last reviewed November 18, 2026 · 9 min read

The short answer

A commercial cannabis flower room is specified as six systems, not a shopping list: benching and canopy, top light, under canopy light, horizontal and in-canopy airflow, dehumidification, and fertigation back to a central water room. On the sample set below, one flower room carries six 18 inch horizontal air flow fans, five floor blowers, a rolling bench grid drawn at both roll positions, top light on its own placement plan, and irrigation zoned to four tables plus a flush line. Each system gets its own placement plan and its own details sheet, because the quantity is set by the room and the part numbers are set by the system.

The six systems, and why they are drawn separately

A flower room is not one order. It is six systems that have to agree with each other, and a change to any one of them moves the others. Raise the canopy and the fan throw changes. Add a tier and the irrigation zone count doubles. Widen the aisle and the bench grid loses a row. That is why a commercial set draws each system on its own placement plan, then details it on a second sheet.

The six systems and the sheets that carry them
SystemPlacement planDetails sheetWhat the plan fixes
Benching and canopyQ1.01, Q1.02Q1.00Bench grid, aisle, both roll positions
Top lightQ2.01Q2.02, Q2.03Fixture layout and PPFD map
Under canopy lightQ3.01Q3.02Fixture runs, power and data
AirflowQ4.01Q4.02Fan positions and throw direction
DehumidificationQ5.01Q5.02Unit placement and capacity
FertigationQ6.01DQ6.02DZones, manifold and injection

Airflow: how many fans, and of what kind

Airflow is specified by room, by fan class and by throw distance, not by air changes per hour. The schedule below is the cultivation fan schedule from the sample set. Four flower rooms, each identical, each carrying two classes of fan: high velocity units moving air the length of the room, and floor blowers moving air through the under canopy.

Cultivation fan equipment schedule, per room
Room14in high velocity18in high velocity8in in-rackFloor blower
Moms34
Veg25
Flower 165
Flower 265
Flower 365
Flower 465
Dry22
Total724922

The split is the point. Flower rooms get the 18 inch units because the room is long and the canopy is dense. Moms and veg get the 14 inch units and in-rack fans, because racking needs air moving between tiers rather than down a hall. The dry room gets the fewest of anything, because the job there is even, slow movement, not velocity.

Fan specifications as published by each manufacturer
TagFixtureAirflowThrowElectrical
HV14APatterson 14in high velocity2,600 CFM60 ft115V / 208-230V, 2.8A / 1.4A
HV18APatterson 18in high velocity3,800 CFM80 ft115V / 208-230V, 6.0A / 3.0-2.9A
VK8Schaefer 8in Versa-Kool, in-rack450 CFMIn-rack115V, 0.6A
VP-25B-Air VP-25 floor blower, 3 speed900 CFMDirectional115V, 1.7 / 1.8 / 2.1A

Throw distance is the number that decides the count. An 80 foot throw in a 60 foot room is not waste, it is the margin that lets the fan work through a full canopy rather than over the top of one. Size on throw against the room length and the canopy depth, then check the amperage against the panel before anyone orders.

Under canopy light: the system people under-order

Under canopy is the system most often priced as fixtures alone and then found short on site, because the fixtures are the cheap half. The sample under canopy layout runs 120 fixtures across four double table rows in a room roughly 66 feet by 30 feet, and the schedule that goes with it is as much cable and control as it is light.

Under canopy lighting equipment schedule, one room
ItemQtyDetail
Under canopy LED fixture12045.6in x 2.9in x 2.3in, 277V, 0.43A, 120W, 2 plant stands per fixture
Controller1Single controller for the room
277V power cable8One per run
Communication line, 10 ft8Splits from the power cable
Waterproof RJ extension, 1 ft8
Waterproof RJ extension, 15 ft8
Splitter8
Outlet / junction box8

Fixtures daisy chain up to 20, which is what sets the run count at eight rather than something arbitrary. Spacing on the drawing is 3 ft 9 5/8 in between fixtures along a table and 5 ft 1 1/2 in between tables, and the sheet carries the line "approximate spacing, field verify based on plant spacing" for a reason: the fixture pitch follows the plant pitch, so a change in plant count changes the order.

Fertigation: what sits behind the room

Fertigation is specified on a piping and instrumentation diagram rather than a plan, because what matters is the order things happen in and where every valve sits, not where the tank is on the floor. The sample P&ID runs from a 3/4 inch water source through filtration to storage, through the stock tanks and the fertigation skid, out to batch tanks, and from there to every table in every room.

Water and fertigation train, in order
StageOn the sample P&ID
Source and filtration3/4in supply into a water filter, normally open and normally closed isolation either side
StorageTwo 750 gallon filtered water tanks
StockSix 55 gallon stock tanks, head tubing to the skid
InjectionFertigation skid, fed from stock, out to the batch tanks
BatchSix 300 gallon batch tanks, each with its own batch tank pump, recirculation, drain and master valve
Distribution1-1/2in PVC mains, 1in PVC to room, solenoid per zone
RoomMothers, veg and moms, and four flower rooms, each zoned per table with a flush line to drain

Every room on the diagram also carries a batch spigot and a water spigot. Those two taps are what let a grower pull a sample or hand water without breaking a zone, and they are the first thing value engineered out of a budget set and the first thing missed once the room runs.

What the part level looks like

The reason a drawing set is worth more than an equipment list is the schedules behind it. A single water room on the sample set carries pipe fitting and accessory schedules running to several hundred line items: 196 one inch socket elbows, 100 one inch male adapters, 66 techlock elbows, 32 solenoids, 1,323 feet of one inch schedule 80 PVC, 1,956 feet of 16 and 17 millimetre PE tubing. That is the level at which a bill of materials either matches the build or does not.

If a quote for a room arrives as six lines and a total, it has not been drawn. It has been estimated, and the difference shows up as change orders during the build.

Common questions

How many fans does a commercial flower room need?

On the sample set, each flower room carries six 18 inch high velocity fans and five floor blowers. The count follows the throw distance against the room length and the canopy depth, not a fixed air changes per hour figure. Moms and veg rooms use a different mix: 14 inch high velocity units plus in-rack fans, because racking needs air between tiers rather than down the length of a hall.

What drawings should a commercial cultivation design set include?

At minimum, a placement plan and a details sheet for each of six systems: benching and canopy, top light, under canopy light, airflow, dehumidification and fertigation, plus floor plans and room elevations. The canopy plan should be drawn at both roll positions if the benching rolls.

Is under canopy lighting priced per fixture?

The fixtures are the smaller half of the order. One room of 120 fixtures on the sample schedule also carries eight power cables, eight communication lines, sixteen waterproof RJ extensions, eight splitters and eight junction boxes. A quote that lists only fixtures and a controller is incomplete.

What is a P&ID and why does fertigation need one?

A piping and instrumentation diagram shows every vessel, pump, valve and line in sequence rather than in plan. Fertigation needs one because the order of operations and the valve positions are what make the system work or fail. A floor plan shows where the tank sits; the P&ID shows what happens to the water.

How we put this together

Every figure on this page is read off the EES sample design set and the cultivation equipment schedules published on our Technical Services page. Quantities are the quantities on the schedule. Where a figure is a manufacturer specification it is named as one and attributed to the fixture.

Elevated designs these rooms and supplies the equipment in them. This page describes how a room is specified, using our own drawings as the worked example.