All resources

How mother, veg, flower and dry rooms differ in specification

Last reviewed November 18, 2026 · 7 min read

The short answer

Room type changes the specification more than room size does. On the sample set, flower rooms get six large horizontal fans and five floor blowers each and are drawn on benching with four irrigation zones. Mother and veg rooms are racked, so they get smaller horizontal fans plus in-rack circulation fans, and their irrigation is drawn as a racking detail with zones per rack level rather than per table. The dry room gets the least of everything, two small horizontal fans and two floor blowers, because its job is even slow movement rather than velocity. Each room type also gets its own irrigation detail sheet, because a table and a rack are plumbed differently.

The specification by room type

What changes between room types
MothersVegFlowerDry
14in horizontal fans3202
18in horizontal fans006 each0
In-rack fans4500
Floor blowers005 each2
CanopyRackedRackedBenchedHanging or racked
Irrigation detailType 2 tableRackingType 1 table and split tableNone
Zones on the P&ID5 plus flushPer rack, A and B, plus flush4 plus flushNone

The pattern is clear once it is in a table. Racked rooms get in-rack fans and no floor blowers, because a floor blower under a rack moves air into the underside of a shelf. Benched rooms get floor blowers and no in-rack fans, because there is a canopy above them with nothing between the floor and it.

Why flower gets the big fans

Flower rooms are the only rooms on this set with 18 inch horizontal fans, rated at 3,800 CFM and an 80 foot throw. Mothers and veg get the 14 inch at 2,600 CFM and 60 feet.

It is not that flower rooms are bigger. It is that a flower canopy in week seven is a wall. Air has to be pushed through leaf rather than across it, and the margin between a published free air throw and what actually penetrates a full canopy is what the larger fan buys. A mother room canopy never gets dense enough to need it.

Why racked rooms are plumbed differently

The sample detail set carries three separate irrigation detail sheets: a type one table detail for flower, a type two table detail for mothers, and a racking irrigation detail for veg and moms. These are three different drawings because they are three different assemblies.

  • A table is fed at one level. A rack is fed at every tier, so the riser and the drops are the design rather than an afterthought.
  • Racking irrigation carries unistrut mounting and pipe clamps on the drawing, because the plumbing is carried by the rack frame rather than sitting on a bench.
  • A rack doubles or triples the zone count for the same floor area, which is why veg zoning on the P&ID runs A and B per rack across five racks rather than one zone per table.
  • Air relief at the top of a riser matters on a rack and does not exist on a table.

The dry room

The dry room takes two 14 inch horizontal fans and two floor blowers, which is the smallest allocation in the building. It carries no irrigation zones at all.

The low fan count is deliberate rather than a saving. A dry room is trying to pull moisture out of material slowly and evenly, and velocity across a hanging crop is the thing that ruins it. The equipment that matters in a dry room is on the dehumidification sheets, not the airflow sheets.

Common questions

How do veg rooms differ from flower rooms in a commercial facility?

Veg rooms on the sample set are racked, so they take smaller horizontal fans plus in-rack circulation fans and no floor blowers, and their irrigation is drawn as a racking detail with zones per rack level. Flower rooms are benched, take the largest horizontal fans plus floor blowers, and are zoned per table.

Why do flower rooms need bigger fans?

A flower canopy late in the cycle is dense enough that air has to be pushed through it rather than across it. The sample set uses 3,800 CFM fans with an 80 foot throw in flower and 2,600 CFM fans with a 60 foot throw in mothers and veg.

How many irrigation zones does a grow room need?

On the sample P&ID, each flower room has four table zones plus a flush zone, mothers has five plus flush, and veg is zoned A and B across five racks plus flush. Racking roughly doubles the zone count for the same floor area.

How much airflow does a dry room need?

Less than any other room. The sample dry room takes two 14 inch horizontal fans and two floor blowers, because the goal is slow even movement rather than velocity. The equipment that matters in a dry room is dehumidification.

How we put this together

Fan counts and classes are read off the cultivation fan equipment schedule. Zone counts and irrigation detail types are read off the P&ID and the sheet list in the EES sample sets.

Elevated designs these rooms and supplies the equipment in them.